Diagnostic Tools
Using BEEP Mode
BEEP Mode is used to verify that the Chronos
Note: If the Chronos System Bridge is not set up as a Main Repeater, this option will not be available.
Step 1
Enter BEEP Mode
From the Chronos System Bridge (as a Main
Repeater only):
Main Menu
System Setup
Diagnostics
Diagnostics
Flash Mode - - - - - - - - No
Beep Mode - - - - - - - - Yes
System Beep Mode - - - No
Back
Use
to highlight Beep Mode. Use
set Beep Mode to Yes.
From a Repeater:
Press and hold the BEEP button on the
Repeater you are checking until the green
BEEP LED turns ON (approximately 3 sec-
onds).
Green BEEP LED on that Repeater only
will be ON.
System Bridge or a Repeater can 'hear' a particular control.
TM
Help
to
Setup Guide for the RadioRA Chronos System Bridge
Step 2
Check a Control
Turn the Lighting Zone Control ON or OFF,
press the ALL ON or ALL OFF button on a
Master Control.
Step 3
Repeater or Chronos System
Bridge response
If the Repeater or Chronos System Bridge can
'hear' the control, it will produce multiple audi-
ble beeps immediately after the button is
pressed.
RF Signal
BEEP
RF Signal
BEEP
89