Helvitica condensed 9 pt italic
C o d e
3 9
Command Code
Summary
R
Exit Test and Service
S
Transmit Printhead
Resistance Values*
T
Transmit Label Taken Sensor
Value
U
Transmit 40 Volt Supply
Value*
V
Transmit Printhead Volt
Supply Value*
;
Command Terminator
*The 4100 printer ignores this command.

User-Defined Interface Tables

The following tables show commands, in the order they must be downloaded,
when you replace the User-Defined Command/Protocol characters. There is a
table for each type of command, as specified by a specific value for t.
1 8
p t
Description
Causes the printer to exit Test and Service mode.
Transmits the average, maximum, and minimum printhead
resistance value back to the host. Each value is a numeric
data string separated by a comma.
Transmits the label taken sensor A/D output back to the
host. The value can range from 00 to 255.
Transmits the 40 volt supply A/D output back to the host.
The range of the value is 00 to 255.
Transmits the printhead volt supply A/D output back to the
host. The range of the value is 00 to 255.
All commands in Test and Service mode must end with the
command terminator except for the last command in a
message.