POSTNET uses the height ("h") and width ("w") commands in the same way
as a font. Other symbologies use "h" to specify the bar height and "w" to
specify the narrow bar width. POSTNET uses "h" and "w" to magnify the base
character cell.
Each character cell is 13 dots high by 22 dots wide. The default width and
height magnification for POSTNET is 2 by 2, resulting in a symbology sized
according to the POSTNET specification.
c16{,m1}{,m2}
The next three modifiers conform to Supplier Standard:
c16,0
c16,1
c16,2,m2
The next four modifiers conform to Provider Standard:
c16,3
c16,4
c16,5,m2
c16,6
Bar Code Field, Create or Edit
Purpose:
Default:
Syntax:
7-48
Helvitica condensed 9 pt italic
C o d e
Select POSTNET.
FrGoth
Selects HIBC Code 128. Default for m1 is 0. m2 is the field
identifier.
Select HIBC Code 128. Primary format.
Select HIBC Code 128. Alternate primary format.
Select HIBC Code 128. Secondary format. The linkage
character comes from m2, which is the field identifier.
Select HIBC Code 128. Single format.
Select HIBC Code 128. First data format.
Select HIBC Code 128. Second data format. The linkage
character comes from m2, which is the field identifier.
Select HIBC Code 128. Multiple data format.
Use this command to edit or create a bar code field n.
n=0
B{n}{,name};
n values can range between 0 and 199.
,name is optional. The field can be up to 8 ASCII
characters, but cannot start with a numeric character.
3 9
1 8
p t
Need help?