Helvitica condensed 9 pt italic
C o d e
3 9
c6{,m1}{,m2}
In 86XX Emulation mode, the Function 1 character can be printed by entering
<SUB> 1. In Advanced mode, the Function 1 character can be printed by
entering <SUB><SUB> 1. The characters for Function 2, 3, and 4 are
represented in the same way.
UCC-128 serial shipping container code automatically starts in subset C and a
<FNC1>. It is a fixed length version of Code 128 requiring 19 numeric
characters to be entered. The first two characters are forced to zeros.
c6,0,0
c6,0,1
c6,1,0
c6,1,1
c7{,m}{,m2}
The variable length option selects the UPC/EAN version by the number of
characters in the data field. The number of data characters and check
characters allowed for each version are:
EAN 8
EAN 13
UPC version A
UPC version E
UPC version D1
UPC version D2
UPC version D3
UPC version D4
UPC version D5
1 8
p t
Select Code 128. The default for m1 is 0 (Code 128). The
default for m2 is 0 (keep parentheses and spaces).
Code 128. Keep parentheses and spaces.
Code 128, ignore parentheses and spaces in the bar code
but keep them in the interpretive field.
Select UCC-128 Serial Shipping Container Code. Keep
parentheses and spaces.
Select UCC-128 Serial Shipping Container Code. Ignore
parentheses and spaces in the bar code but keep them in
the interpretive.
Select UPC/EAN Codes. Default for m1 is 0.
7 data + 1 check character
12 data + 1 check character
11 data + 1 check character
6 data + 1 check character
13 data + 1 check character
18 data + 2 check characters
22 data + 2 check characters
25 data + 3 check characters
29 data + 3 check characters
7