For your printer to print Mode 2 and 3 compatible symbols, you must
restructure the data:

HIBC Code 128

Syntax:
c16[ ,m1 ][ ,m2 ]
The following three modifiers conform to Supplier Standard:
c16,0
c16,1
c16,2, m2
The following four modifiers conform to Provider Standard:
c16,3
c16,4
c16,5, m2
c16,6
Default:
,m1 = 0

Bar Code Field, Create/Edit

Purpose:
Use this command to edit or create a bar code field n.
Syntax:
B n [, name ]
n values can range between 0 and 199.
,name is an optional field. The field can be up to eight ASCII characters (not
counting the semicolon) and cannot start with a numeric character.
6-50
Insert the Mode 2 and 3 header immediately after the country code at the
beginning of the secondary message.
Make the fields contiguous and fill in all fields.
Swap the order of the country code (field 4) and the service class (field 3).
Terminate your data with an uppercase D.
No control characters (
Select HIBC Code 128, primary format.
Select HIBC Code 128, alternate primary format.
Select HIBC Code 128, secondary format. The linkage character
comes from ,m2, which is the field identifier.
Single format.
First data format.
Select HIBC Code 128. Second data format. The linkage
character comes from ,m2, which is the field identifier.
Select HIBC Code 128. Multiple data format.
R
G
or
) in the primary message.
S
S