PBV20N2
PBV20N2
PARAMETER
PARAMETER
Check up done
Check up done
CHECK UP DONE
CHECK UP DONE
Check up type
Check up type
CHECK UP TYPE
CHECK UP TYPE
Electrobrake retain voltage
Electrobrake retain voltage
EB VOLTAGE RED.
EB VOLTAGE RED.
Fan start temperature
Fan start temperature
FAN
FAN TEMPERATURE
TEMPERATURE
Main contactor retain voltage
Main contactor retain voltage
MC VOLTAGE RED.
MC VOLTAGE RED.
Maximum lifting time
Maximum lifting time
MAX LIFT TIME
MAX LIFT TIME
Throttle 0 zone
Throttle 0 zone
THROTTLE 0 ZONE
THROTTLE 0 ZONE
Throttle curve X-axis
Throttle curve X-axis
THROTTLE X POINT
THROTTLE X POINT
Throttle curve Y-axis
Throttle curve Y-axis
THROTTLE Y POINT
THROTTLE Y POINT
https://www.forkliftpdfmanuals.com/
Document ID: 615023
Document ID: 615023
Service
Service Manual
DESCRIPTION
DESCRIPTION
Maintenance request acknowledgement.
Maintenance request acknowledgement.
 
 
0 = No maintenance warnings.
0 = No maintenance warnings.
 
 
1 = Maintenance warning in 600 h.
1 = Maintenance warning in 600 h.
 
 
2 = Maintenance warning in 600 h, speed
2 = Maintenance warning in 600 h, speed
reduction in 640 h.
reduction in 640 h.
 
 
3 = Maintenance warning in 600 h, speed
3 = Maintenance warning in 600 h, speed
reduction in 640 h, truck stop in 680 h.
reduction in 640 h, truck stop in 680 h.
This parameter controls the brake coil voltage one
This parameter controls the brake coil voltage one
second after the activation of the brake voltage. The
second after the activation of the
parameter should be set between 60% and 80%.
parameter should be set between 60% and 80%.
Value range:
Value range:
 
 
0%: Minimum
0%: Minimum
 
 
100%: Maximum
100%: Maximum
This parameter controls the temperature limit for
This parameter controls the temperature limit for
fans. If any of the measured temperatures exceed
fans. If any of the
measured temperatures exceeds s
this value, the fans are started.
this value, the fans are started.
This parameter controls the main contactor coil
This parameter controls the main contactor coil
voltage one second after the activation of
voltage one second after the activation of the main
contactor voltage.
contactor voltage.
Value range:
Value range:
 
 
0%: Minimum
0%: Minimum
 
 
100%: Maximum
100%: Maximum
Maximum lift time adjustment.
Maximum lift time adjustment.
 
 
Level = 3: Minimum
Level = 3: Minimum
 
 
Level = 15: Maximum
Level = 15: Maximum
This parameter establishes the dead band in the
This parameter establishes the dead band in
finger tip input curve (see Figure 86
finger tip input curve (see
 Figure 86 below).
This parameter changes the characteristics of the
This parameter changes the characteristics of the
finger tip input curve (see Figure 86
finger tip input curve (see
 Figure 86 below).
This parameter changes the characteristics of the
This parameter changes the characteristics of the
finger tip input curve (see Figure 86
finger tip input curve (see
 Figure 86 below).
150 (244)
150 (244) 
 
Manual
brake voltage. The
the main
the
below).
below).
below).