Profimess SW-08 Operating Instructions Manual page 63

Varible area flowswitch
Table of Contents

Advertisement

Fig. 52: Tighten process connection
(outlet)
Using a proper sized fixed
11.
spanner tighten the process con-
nection (outlet). Hold the device
body in place using a suitable
fixed spanner(Fig. 52), and
observe the proper torque
(
Ä
Chapter 11.1 "Tightening
torque" on page 74)
20.02.2015
Fig. 53: Check for smooth operation
Check the float for ease of
12.
movement (Fig. 53) by applying
light pressure with the test rod
ð If the float moves sluggishly,
then disassemble the device
Ä
Chapter 9.2 "Disas-
sembly" on page 66 and
clean the float and device
body bore
If the float is still sluggish after
having been cleaned several
times, contact the manufacturer.
Maintenance
Maintenance > Assembly