Profimess SW-08 Operating Instructions Manual page 142

Varible area flowswitch
Table of Contents

Advertisement

Fig. 55: Tighten process connection
(outlet)
Using a proper sized fixed
11.
spanner, tighten the process
connection (outlet). Hold the
device body in place using a
suitable fixed spanner (Fig. 55),
and observe the proper torque
(
Ä
Chapter 11.1 "Tightening
torque" on page 78).
23.02.2015
Fig. 56: Check for smooth operation
Check the float for ease of
12.
movement (Fig. 56) by applying
light pressure with the test rod.
ð If the float moves sluggishly,
then disassemble the device
Ä
Chapter 9.2 "Disas-
sembly" on page 70 and
clean the float and device
body bore.
If the float is still slug-
gish after having been
cleaned several times,
contact the manufac-
turer.
Fig. 57
Position the display base plate
13.
onto the device body and lightly
tighten the fixing screws so that
the base plate can still be moved
(Fig. 57). Make sure that the