Maintenance; Cleaning - Profimess SW-08 Operating Instructions Manual

Varible area flowswitch
Table of Contents

Advertisement

Insert socket wrench into the
16.
threaded ring insertion tool and
loosen the threaded ring
(Fig. 51). Hold the device body
in place using a proper sized
spanner wrench.
Fig. 52: Remove threaded ring (inlet)
17.
Unscrew the threaded ring (inlet)
from the device body (Fig. 52)
O-ring replacement
It is recommended that the O-rings
be replaced during maintenance.

8.5 Maintenance

23.02.2015

8.5.1 Cleaning

It is the responsibility of the operator to
establish appropriate intervals and pro-
cedures for cleaning the individual
parts of the device. It must be ensured
that the parts are not damaged during
the cleaning process. When using
cleaning agents, it must be ensured
that these are not aggressive to the
parts and that there will be no dan-
gerous reactions with media residue.
Damaged parts must be replaced.
WARNING!
Risk of injury due to improper
cleaning!
The device may still contain media
residue.
To protect against hazardous
media residue in the device,
wear personal protective
equipment.
Do not use cleaning agents
which may lead to dangerous
reactions with media residue.
All requirements specified in
the safety data sheet must be
observed when handling or
otherwise using the medium.
Residue of hazardous media
inside the device can cause
serious injury.
Maintenance
Maintenance > Cleaning
61

Advertisement

Table of Contents
loading