Maintenance
Disassembly
Fig. 39: Remove inner parts
Carefully turn the device body
6.
180° and remove the inner parts
(float, magnets and spring)
(Fig. 39)
Fig. 40: Spring, magnets and float
56
The inner parts of the flow mon-
7.
itor consist of the (Fig. 40/01)
spring, (Fig. 40/02) magnets and
(Fig. 40/03) float.
Fig. 41: Loosen process connection
(inlet)
8.
Loosen the process connection
(inlet) (Fig. 41) using the proper
sized fixed spanner wrench.
Hold the device body in place
using a proper sized spanner
wrench