Installation and initial startup
Installation in the pipe system
Apply sealing thread (Fig. 10/1)
2.
to the napped thread in the
threaded direction. Observe the
quantity recommended by the
sealant manufacturer.
Fig. 11: Pipe connection with sealing
thread
ð The pipe line is now ready
for installation (Fig. 11)
34
Install device in pipe system
Personnel:
Qualified personnel
n
Protective equipment:
n
Protective gloves
Tool:
n
Fixed spanner
CAUTION!
Do not hold the device by the
threads. These are sharp edged
and may cause injury.
Place the threaded end of the
1.
device onto the thread of the
connecting pipe
Fig. 12: Screw in the device
2.
Fasten the adapter union of the
pipeline with an appropriate
spanner (Fig. 12/2). When doing
so, lock the process connector in
place to prevent slip, using a
suitable spanner (Fig. 12/1).
23.02.2015