Fig. 58: Check for smooth operation
Check the float for ease of
14.
movement (Fig. 58) by applying
pressure with the test rod
ð If the float moves sluggishly,
then disassemble the device
Ä
Chapter 9.2 "Disas-
sembly" on page 69 and
clean the float and device
body bore
If the float is still sluggish after
having been cleaned several
times, contact the manufacturer.
20.02.2015
Maintenance > Switch contact replacement
8.5.4 Switch contact
replacement
Tool:
Flat-bladed screwdriver
n
Fig. 59: Loosen female socket
Loosen the fixing screw of the
1.
female socket (Fig. 59) with a
flat-bladed screwdriver.
Fig. 60: Remove female socket
Remove the female socket and
2.
gasket (Fig. 60/01) by pulling
upwards.