Maintenance
Maintenance > Assembly
Lightly seat the threaded ring
11.
(outlet) with the aid of the
threaded ring insertion tool and
tighten with a torque wrench
(Fig. 55), observing the proper
torque (
Ä
Chapter 11.1 "Tight-
ening torque" on page 79)
Fig. 56: Insert process connection
(outlet)
12.
Insert the process connection
(outlet) into the device body
(outlet) (Fig. 56)
64
Fig. 57: Tighten process connection
(outlet)
Using a proper sized fixed
13.
spanner tighten the process con-
nection (outlet). Hold the device
body in place using a suitable
fixed spanner(Fig. 57), and
observe the proper torque
(
Ä
Chapter 11.1 "Tightening
torque" on page 79)
20.02.2015