Chapter 1: VC707 Evaluation Board Features
Table 1-15
Table 1-15: FPGA U1 to SFP+ Module Connections
Table 1-16
Table 1-16: SFP+ Module Control and Status
SFP_TX_FAULT
SFP_TX_DISABLE
SFP_MOD_DETECT
SFP_RS0
SFP_RS1
SFP_LOS
10/100/1000 Tri-Speed Ethernet PHY
[Figure
The VC707 board utilizes the Marvell Alaska PHY device (88E1111) U50 for Ethernet
communications at 10, 100, or 1000 Mb/s. The board supports SGMII mode only. The PHY
connection to a user-provided Ethernet cable is through a Halo HFJ11-1G01E RJ-45
connector (P4) with built-in magnetics.
On power-up, or on reset, the PHY is configured to operate in SGMII mode with PHY
address 0b00111 using the settings shown in
by software commands passed over the MDIO interface.
40
Send Feedback
lists the SFP+ module RX and TX connections to the FPGA.
FPGA (U1) Pin
Schematic Net Name
AL5
AL6
AM4
AM3
AP33
SFP_TX_DISABLE_TRANS
lists the SFP+ module control and status connections to the FPGA.
SFP Control/Status
Signal
Test Point J22
Jumper J6
Test Point J21
Jumper J38
Jumper J39
Test Point J20
1-2, callout 15]
www.xilinx.com
SFP_RX_N
SFP_RX_P
SFP_TX_P
SFP_TX_N
Board Connection
High = Fault
Low = Normal Operation
Off = SFP Disabled
On = SFP Enabled
High = Module Not Present
Low = Module Present
Jumper Pins 1-2 = Full RX Bandwidth
Jumper Pins 2-3 = Reduced RX Bandwidth
Jumper Pins 1-2 = Full TX Bandwidth
Jumper Pins 2-3 = Reduced TX Bandwidth
High = Loss of Receiver Signal
Low = Normal Operation
Table
1-17. These settings can be overwritten
SFP+ Module (P3)
Pin
Name
12
RD_N
13
RD_P
18
TD_P
19
TD_N
3
TX_DISABLE
VC707 Evaluation Board
UG885 (v1.4) May 12, 2014