15.5.2 Data

There is a difference between the transfer of cyclical and non-cyclical data.

15.5.2.1 Cyclical data

Cyclical data is data that is sent between the device and the PLC at regular intervals. The cycle is defined via
the PLC configuration.
Cyclical data is grouped into different modules. The consistency of the data can only be ensured within a
module. If multiple modules in the PLC are interconnected (e.g. new trigger data for each trigger), this must
be taken into account.
For example, you must ensure that the trigger in the control and status module is triggered after the new
trigger data in the trigger data module. This can be achieved by setting the HS flag at the correct time.
If the cyclical data changes, the corresponding reactions are triggered. If the handshake is used, this only
happens when the handshake flag changes. When the connection is first established, actions are triggered
for some data even if this data does not change.
Element
Behaviour on initial receipt
Trigger
Is not analysed, is only stored to detect changes
Is analysed, 0 received → deactivate teach, 1 received → activate teach
Teach
Is analysed, 0 received → Run mode is triggered, 1 received → Set-up mode is
Operating Mode
triggered
Current job
Is analysed, 0 received → no change, all other values → switch to the given job
number
Reset Statistics
Is not analysed, is only stored to detect changes
Reset State SJ
Is not analysed, is only stored to detect changes
Reset State SP
Is not analysed, is only stored to detect changes
Reset State SM
Is not analysed, is only stored to detect changes
SetParam
"Immediately" used
TriggerData
"Immediately" used, data is scheduled for next image acquisition
Below there is a description of the individual data elements that could be exchanged in different compilations
depending on the protocol used.
v2.8.2-K11
297/332
Technical Documentation
opti-check
ipf electronic GmbH
Lüdenscheid, Germany

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the opti-check and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents