15.4.9 SJ command – change to a different job
This function enables you to change to a different job.
To use this function, you must first activate the option Command SJ via process interface in the device
settings.
Example
Structure of the command PLC
Command
Parameters
S
J
0
Switch Job
4 byte ASCII hex
desired job number
Structure of the Response PLC
Response
R
S
0
Response
4 byte ASCII hex
State
Status
NOTE
Further explanation of the parameters of the RS response can be found under "Request
status (GS / RS)".
v2.8.2-K11
device
0
1
A
device
0
8
5
4 byte ASCII hex
Number of the active job
0
0
1
A
281/332