Uj Command - Transfer A New Job - ipf electronic opti-check Technical Documentation Manual

Hide thumbs Also See for opti-check:
Table of Contents

Advertisement

15.4.17 UJ command – transfer a new job
This function enables you to transfer a new job to the device.
NOTE
The job name including the file extension ".app" can be a maximum of 31 characters.
NOTE
Jobs cannot be renamed on the PC when using the UJ command for job transfers.
Example
Structure of the command PLC
Command
Parameters
U
J
0
0
Update Job
4 byte ASCII hex
job number
Structure of the Response PLC
Response
R
U
0
Response
00 = received OK
Update
01 = device not in SETUP mode
02 = invalid job number
03 = job could not be loaded
04 = job update still active
05 = invalid network settings
06 = invalid device name
07 = backup file device type not identical to the device
08 = user management is active
09 = device file is password protected
10 = file could not be opened for writing
11 = file write error
12 = incompatible backup
13 = only the firmware cannot be imported
other = internal fault
v2.8.2-K11
device
0
3
0
0
0
8 byte ASCII hex
Job size
device
0
4
F
9
E
2
294/332
Technical Documentation
...
Job as binary data
ipf electronic GmbH