15.4.2 Command GB – access device backup
This function enables you to access a backup of the device with firmware or the job as well as the device
settings.
Example
Structure of the command PLC
Command
Parameters
G
B
0
Get
0000 = Backup with firmware
Backup
0001 = Only jobs and device settings
Structure of the Response PLC
Response
R
B
0
Response
4 byte ASCII hex
Backup
Parameters of the GB-
command
Error messages:
F001 = Device is not
F004 = Backup has already
F008 = Password protection
v2.8.2-K11
device
0
0
0
device
0
0
0
deactivated
been called
activated
0
0
0
4
F
8 Byte ASCII-Hex data length
(32bit)
For errors, the length is 0