5.
Pull the recoil rope tight in the recoil sheave.
a
6.
Assemble the recoil pawl as shown.
7.
Lubricate the starter pawl bore on the recoil sheave with 2‑4‑C with PTFE.
8.
Install the starter pawl return spring onto the recoil sheave.
9.
Install the starter pawl onto the recoil sheave.
Tube Ref No.
2-4-C with PTFE
95
10. Secure starter pawl with the E‑ring retained during disassembly.
90-8M0105568 eng MARCH 2016
a
b
Description
a -
To recoil handle
9727
a -
Starter pawl
b -
Starter pawl return spring
9730
Where Used
Starter pawl bore on the recoil sheave
9725
© 2016 Mercury Marine
Recoil Starter
9728
Part No.
92-802859A 1
Page 8A-9