Configuration; Front Panel; Scpi - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

Remote Operation
Table 4-5 CANbus Pins

Configuration

Before connecting a power supply to a multichannel network, you must configure
each power supply with a unique address. The front panel or a remote interface
maybe used to do this.
One power supply must be configured to operate via RS-232 or GPIB.

Front Panel

1. Select the "REMOTE CONFIG" menu
2. Select the "Multichnl Cfg" menu. Press ENTER.
3. When prompted with "Addr" enter a unique network address in the range 1–
To receive and execute commands:
◆ Select the "REMOTE SELECT" menu, then select "Multichannel" from

SCPI

Set a slave's multichannel address using the command:
SYSTem:COMMunicate:MCHannel:ADDRess <multichannel-address>
where multichannel-address is an integer in the range of 1-50, and the command is
sent via a controller directly connected to the slave's RS-232 port.
If the unit is to execute commands, set the power supply to accept control via
multichannel commands (the CANbus interface) with the SCPI command:
SYSTem:REMote:SOURce MCHannel
4–12
Pin #
Function
8
Not used
9
Not used
50. Press ENTER
the list. Press ENTER.
TM-XDOP-01XN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents