Remote Operation

TEMPerature Sub-Register

This shows whether the temperature of critical components is near or over the
maximum operating temperature.

Table 4-19 TEMPerature Sub-Register

Bit
Bit Weight
0
1
1
2

Standard Event Status Register

The standard event status register sets bits for specific events during power supply
operation. All bits in the standard event status registers are set through the error
event queue. The register is defined by 488.2 and is controlled using 488.2
common commands, *ESE, *ESE?, and *ESR?.
Figure 4-6, "IEEE 488.2 Status Register and Status Byte" on page 4–54
summarizes the standard Event Status Register.
Operation Complete
Query Error
Device Dependent Error
Execution Error
Command Error
User Request
Power On
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Standard Event Status Register

Figure 4-6 IEEE 488.2 Status Register and Status Byte

4–54
Bit Name
Over TEMperature Set if the power supply temperature exceeds the maximum
High TEMperature Set if the power supply temperature exceeds 90% of the
0
Not Used
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Description
operating temperature.
maximum operating temperature.
Summary of QUESTionable Status
+
Summary of OPERation Status
Not Used
0
Not Used
1
Not Used
2
3
MAV
4
5
RQS/MSS
6
7
TM-XDOP-01XN