Set V, I, And P Limits - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

To lock out only the Voltage knob:
If you attempt to use the Voltage knob, the display shows V Knob Locked, and
the output is not affected. If you attempt to use the Current knob, the knob
operates normally. You can also lock the Current knob without locking the Voltage
knob. To unlock the knobs, repeat the steps above, and select N for Lock _ Knob?

Set V, I, and P Limits

The voltage, current and power setpoints can be limited to less than the supply
rating range to match the tolerance of connected equipment or any other criteria
you may have.
You can control the voltage, current and power setpoint limits through the SETPT
LIMIT menu option. Once the limits have been changed from the supply's
default rated output, settings outside this range are no longer accepted.
Before setting voltage, current or power setpoint limits, make sure that the
voltage, current or power setpoint is set to a value between the desired upper and
lower setpoint limits.
Important:
outputs.
TM-XDOP-01XN
Step # Do This
1
MENU
2
until you see the "KNOB
LOCKOUT" option
3
ENTER
4
5
ENTER
6
ENTER
Setpoint limits do not apply to the triggered outputs and auto sequence
Power Supply Operation
You Will See
ERROR MSGS
KNOB LOCKOUT
Lock V Knob? N
Lock V Knob? Y
Lock I Knob? N
The Voltage knob is locked out.
The Current knob is not locked
out. This setting is saved, and
the display returns to its default
operating mode.
3–45