Table C-3 Commands For Output Control - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

Table C-3 Commands for Output Control

Function
SCPI Command
Set (Immediate)
[[:]SOURce][<channel>]:CURRent[:LEVel][:IMMediat
Current Setpoint
e][:AMPLitude] {<current>|MAXimum|MINimum}
Set Triggered
[[:]SOURce][<channel>]:CURRent[:LEVel]:TRIGgered
Current Setpoint
[:AMPLitude] {<current>|MAXimum|MINimum|DEFault}
Set (Immediate)
[[:]SOURce][<channel>]:POWer[:LEVel][:IMMediate]
Power Setpoint
[:AMPLitude] {<power>|MAXimum|MINimum}
Set Triggered
[[:]SOURce][<channel>]:POWer[:LEVel]:TRIGgered[:
Power Setpoint
AMPLitude] {<power>|MAXimum|MINimum|DEFault}
Set (Immediate)
[[:]SOURce][<channel>]:VOLTage[:LEVel][:IMMediat
Voltage Setpoint
e][:AMPLitude] {<voltage>|MAXimum|MINimum}
Set Triggered
[[:]SOURce][<channel>]:VOLTage[:LEVel]:TRIGgered
Voltage Setpoint
[:AMPLitude] {<voltage>|MAXimum|MINimum|DEFault}
Set Voltage Slew
[[:]SOURce][<channel>]:VOLTage:SLEW:STEP{<slewra
Rate Voltage
te-voltage>|MAXimum|MINimum|DEFault}
Set Voltage Slew
[[:]SOURce][<channel>]:VOLTage:SLEW:INTerval{<sl
Rate Interval
ewrate-interval>|MAXimum|MINimum|DEFault}
Set Over Current
[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]
Protection Level
[:LEVel] {<current>|MAXimum|MINimum}
Set Over Current
[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]
Protection
:STATe <on-off-state>
Shutdown State
Query Over
[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]
Current Protection
:TRIPped?
Tripped
Set Under Current
[[:]SOURce][<channel>]:CURRent:PROTection:UNDer[
Protection Level
:LEVel] {<current>|MAXimum|MINimum}
Set Under Current
[[:]SOURce][<channel>]:CURRent:PROTection:UNDer:
Protection
STATe <on-off-state>
Shutdown State
Description
Change current setpoint
Change triggered current setpoint
Change power setpoint
Change triggered power setpoint
Change voltage setpoint
Change triggered voltage setpoint Yes
Sets the voltage slew rate voltage
change for the programmed time
interval
Sets the voltage slew rate time
interval for the programmed
voltage change
Set the over current protection
level
Select over current protection to
shutdown (ON) or set alarm
(OFF)
Query if over current protection
mechanism has tripped
Set under current protection level
Select under current protection to
shutdown (ON) or set alarm
(OFF)
Query
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes