Execution Error List; Table D-2 Execution Error List - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

Execution Error List

An error in the range [-299, -200] indicates that an error has been detected by the
instrument's execution control block. The occurrence of any error in the class
causes the execution error bit (bit 4) in the Event Status Register to be set.
Execution errors are reported by the device after rounding and expression
evaluation operations have taken place.

Table D-2 Execution Error List

TM-XDOP-01XN
Error code Error Message Description
-200
Execution error
This is the generic error for the power supply.
-203
Command protected
Indicates that a legal password-protected program command or query could
not be executed because the command was disabled. Check calibration state.
-220
Parameter error
Indicates that a program data element related error occurred.
-221
Setting conflict
Indicates that a legal program data element was parsed but could not be
executed due to the current power supply state.
Factors that may contribute to this error are:
Remote source - To set most values, the remote source must be correct.
Remote state - To set most values, the unit must be in remote mode.
Calibration mode - when in calibration mode, certain settings will cause as
error.
Current share mode - When the unit is in current share mode (other than
none) certain settings will cause an error.
-222
Data out of range
Indicates that a legal command could not be executed because the interpreted
value was outside the legal range as defined by the power supply.
-225
Out of memory
The power supply has insufficient memory to perform the requested
operation.
-231
Data questionable
Indicates that measurement accuracy is suspect.
-240
Hardware error (occurs during flash update if there is a failure)
Indicates that a legal program command or query could not be executed
because of a hardware problem in the power supply.
-241
Hardware missing
Indicates that a legal program command or query could not be executed
because of missing power supply hardware; e.g. an option not installed.
-282
Illegal program name
The name used to reference an auto sequence program was invalid or there is
no program selected.