Overview; Command Error List; Table D-1 Command Error List - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

Error Messages

Overview

Errors are placed in a queue as they are detected. The queue works on a first in,
first out (FIFO) basis. If the queue overflows, the last error in the queue is
replaced with error –350, "Queue Overflow". When all errors have been read
from the queue, further error queries return 0, "No error".
The error queue is cleared when any of the following occur (IEEE 488.2, section
11.4.3.4):
All negative values are reserved by the SCPI standard. All errors unique to the
power supply have positive values.

Command Error List

An error in the range [-199, -100] indicates that an IEEE 488.2 syntax error has
been detected by the instrument's parser. The occurrence of any error in this class
causes the command error bit (bit 5) in the Event Status Register to be set.

Table D-1 Command Error List

Error code Error Message Description
-100
-105
-114
-120
-123
-151
D–2
Upon receipt of a *CLS command
Upon reading the last item from the queue
Command error
This is the generic syntax error.
GET not allowed
A Group Execute Trigger was received within a program message.
Header suffix out of range
The value of a numeric suffix attached to a program mnemonic is out of
range. May refer to multichannel addressing, auto sequence number or auto
sequence step number.
Numeric data error
This error is generated when parsing a data element which appears to be
numeric, including the non-decimal numeric types.
Exponent too large
The magnitude of the exponent was larger than 32000.
Invalid string data
The data with the enclosed (") double apostrophes (string) is invalid.
Possibility of wrong length or character.
TM-XDOP-01XN

Hide quick links:

Advertisement

Table of Contents
loading