6. Ensure that the positive and negative wires are arranged so bare wires do not
To connect the DC output wire clamp connectors (300V, 600V outputs):
◆ Connect appropriately sized wires as described in steps 1 to 6 above, except

Multiple Loads

To connect multiple loads in parallel:
◆ Follow the "Single Load" procedure with the following exception:

Figure 2-7 Fastening the Output Wires (6000 Watt)

TM-XDOP-01XN
come into contact with each other or the chassis.
strip 0.5 in. (14mm) of insulation off each load wire, and clamp in the output
connector by securely tightening the vertical clamp screw for each output.
To minimize interaction between loads, bring the wiring for each load directly
back to the supply output. When each load to the power supply is wired
separately, the loads will see only the precisely regulated output from the
supply. If 2 loads share a single cable, the fluctuation in current to one load
will cause the voltage to vary on the others. This is due to wire impedance
drops.
(low and medium voltage)
Load Connections
2–19