Current Share
Units are programmed in a mode such that it is already in current sharing mode on
Configuration
power up. This feature is not user-modifiable. Please contact the manufacturer for
assistance if you wish to change this.
Most configurable settings available on a master 6kW unit are disabled on the slave
units for protection. All the queries are still available.
Setup
To set up multiple supplies for current share operation, follow these steps:
Current
1. Power down the units. Connect the CAN ports of all paralleled units as explained
Sharing
Network
2. Make load connections. It is recommended to keep load cables the same length
3. Power up the master.
4. Power up the slaves one at a time.
5. Set the voltage and current on the master, then enable the output.
Release 1.0
in "CANbus Setup".
if possible. See Figure 3.1.
Current Sharing
Overview