Operation

Configure Remote Control Source

The REMOTE CONFIG menu option lets you set up the attributes of the remote
control sources.
The following table shows how to access and work with the Remote
Configuration option.
Step # Do This
1
2
3
4
5
a. You can also press MENU 5 times.
After you have selected the remote control source you want to configure,
configure that setting using appropriate values from the following table. Select
values using the arrow keys or the numeric keypad. To save a value you have
selected, press ENTER.
See Chapter 4, "Remote Operation" for detailed instructions on setting up remote
interfaces.
Remote Control
Source
RS-232
Analog
GPIB
Multichannel
a. This range depends on the user's network configuration.
b. Hdwr = hardware handshake; XON = software flow control XON/XOFF characters used;
3–20
MENU
a
5 times
ENTER
or
Press repeatedly until the desired
remote control source appears.
ENTER
Prompt
Baud ######
Flow Ctl ####
Input #### V
GPIB Addr ##
PON SRQ? Y
Slave Addr ##
Connect?
None = no flow control
You Will See
ERROR MSGS
REMOTE CONFIG
RS-232 Cfg
RS-232 Cfg
Analog Cfg
GPIB Cfg
Multichnl Cfg
See the tables that follow to see
how to proceed.
Configuration Settings
1200, 2400, 4800, 9600, 19200, 38400
b
Hdwr, XON, None
Select the operating range of the API:
0–5
0–10
1–30
Y, N
2-50
Y, N
a