Shipped
The factory ships units already configured for local control (front panel) operation.
Configuration
See Table 3.1 for a summary of this configuration.
Table 3.1 Shipped Configuration (Local Control Mode)
Local Control Configuration
Use the front panel controls to adjust the output
voltage and current limit settings. (Note: Use
the LOCAL button only when you have a digital
programming interface installed.)
The supply's sense point is at the rear panel
J10 sense connector terminals.
The OVP set point is adjusted at the front panel
to approximately 110% of rated output voltage.
The over temperature shutdown function
automatically resets when activated as
determined by the position of rear panel switch
SW1-8. A latch off setting is also available.
Release 3.1
Local Operation
Standard Operation
Additional References
See Section 3 for front panel
operation. See Section 4 for remote
analog programming procedure(s).
"Local and Remote Sensing"
See
on page 53
for how to change from
local to remote sensing.
"Using Over Voltage
See
Protection (OVP)" on page 61
the adjustment procedure.
"Over Temperature Protection
See
(OTP)" on page 70
for more
information about switch SW1-8
settings.
for
59