Regulating Sub-Register; Shutdown Sub-Register; Table 4-10 Regulating Sub-Register; Table 4-11 Shutdown Sub-Register - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

REGulating Sub-Register

This describes the regulating mode. If none of these bits is active, the output
unregulated (UNRegulated) bit is active in the questionable status register.

Table 4-10 REGulating Sub-Register

Bit
Bit Weight
0
1
1
2
2
4

SHUTdown Sub-Register

Describes the cause of the power supply shutting down. More than one bit may be
active, and multiple actions will be required to restart the unit. The protection
shutdown sub-register indicates which protection mechanisms have caused the
power supply to shutdown.

Table 4-11 SHUTdown Sub-Register

Bit
Bit Weight
0
1
1
2
2
4
TM-XDOP-01XN
Bit Name
Description
CV
The power supply is regulating in Constant Voltage mode.
CC
The power supply is regulating in Constant Current mode.
CP
The power supply is regulating in Constant Power mode.
Bit Name
Description
PROTection
The power supply is shut down by a power supply protection
Summary
mechanism.
INTerlock
The power supply is shut down by INTerlock signal.
COMMand
The power supply is shut down by a command.
SCPI Commands for Digital Interfaces
4–47