Xantrex XDC 10-1200 Operating Manual page 75

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

To set the Over-Power Protection:
To set the Under-Power Protection:
TM-XDOP-01XN
Step # Do This
1
PROT SET
ALARMS
2
PROT SET
Press repeatedly until the desired setting
ALARMS
appears.
3
ENTER
4
Use both the Current and Voltage knobs, or the
numeric keypad, or the arrow keys to enter a value.
The value must be between 0W and 103% of the
unit's rated power.
5
ENTER
6
Use the arrow keys to select Yes or No. For this
example, Yes is selected.
7
ENTER
Step # Do This
1
PROT SET
ALARMS
2
Press repeatedly until the desired setting
PROT SET
ALARMS
appears.
3
ENTER
4
Use both the Current and Voltage knobs, or the
numeric keypad, or the arrow keys to enter a value
(must be between 0W and 103% of the unit's rated
power).
5
ENTER
6
Use the arrow keys to select Yes or No. For this
example, Yes is selected.
7
ENTER
Power Supply Operation
You Will See
OVP SET 0V
OPP SET 0W
OPP SET 0W
OPP SET ####W
S/D if trip? N
S/D if trip? Y
This setting is saved and
the display returns to its
default operating mode.
You Will See
OVP SET 0V
UPP SET 0W
UPP SET 0W
UPP SET ####W
S/D if trip? N
S/D if trip? Y
This setting is saved and
the display returns to its
default operating mode.
3–13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents