Program Auto Sequence; Programming A Sequence; Table 3-2 To Program A Sequence - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

Program Auto Sequence

The AUTO SEQ PGM menu option is used to set up command programs for
automated operation. There are 10 programmable sequences with up to 99 steps
per sequence.
Each sequence can be repeated a programmable number of times or forever. If the
sequence contains steps that advance by a trigger event, a single trigger source can
be selected to advance those steps.
Each step can be programmed to set the voltage setpoint, current setpoint, power
setpoint, and OVP level automatically. Each step can also be programmed to
advance by a delayed time or a trigger event. The duration of each step may range
from 10 ms to 99 hours.

Programming a Sequence

This option allows you to set up command programs for automated operation.
To program a sequence:
Important:
Otherwise simply press

Table 3-2 To Program a Sequence

TM-XDOP-01XN
In the following procedure, only change the default setpoints if required.
ENTER
Step # Do This
1
MENU
2
or
3
ENTER
4
or
select a sequence to work with.
5
ENTER
6
Edit mode is selected
ENTER
7
ENTER
8
Enter the step voltage setpoint
ENTER
9
Enter the step current setpoint.
ENTER
10
Enter the step power.
ENTER
to accept.
6 times
MENU
. Use the scroll keys to
Power Supply Operation
You Will See
ERROR MSGS
AUTO SEQ PGM
Sequence 1
Sequence #
Edit Sequence
Step 1
Edit Step
S01 ####V
S01 ####A
S01 ####W
3–33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents