Voltage Sub-Register; Current Sub-Register; Power Sub-Register; Table 4-16 Voltage Sub-Register - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

VOLTage Sub-Register

This shows whether the present voltage level is over or under the specified trip
limit.

Table 4-16 VOLTage Sub-Register

Bit
Bit Weight
0
1
1
2

CURRent Sub-Register

This shows whether the present current level is over or under the specified trip
limit.

Table 4-17 CURRent Sub-Register

Bit
Bit Weight
0
1
1
2

POWer Sub-Register

This shows whether the present power level is over or under the specified trip
limit.

Table 4-18 POWer Sub-Register

Bit
Bit Weight
0
1
1
2
TM-XDOP-01XN
Bit Name
Description
Over VOLtage
Set if the supply's output voltage exceeds the over-voltage trip
level, either user-specified variable trip limit, or the fixed trip
limit.
Under VOLtage
Set if the supply's output voltage is less than the user-specified
under-voltage trip level (variable trip limit) and the supply is in
Operation state.
Bit Name
Description
Over CURrent
Set if the supply's output current is greater than the user-
specified over-current trip level (variable trip limit) and the
supply is in Operation state.
Under CURrent
Set if the supply's output current is less than the user-specified
under current trip level (variable trip limit) and the supply is in
Operation state.
Bit Name
Description
Over POWer
Set if the supply's output power is greater than the user-
specified over-power trip level (variable trip limit), and the
supply is in Operation state.
Under POWer
Set if the supply's output power is less than the user-specified
under-power trip level (variable trip limit), and the supply is in
Operation state.
SCPI Commands for Digital Interfaces