Table C-11 Protection Commands

Function
SCPI Command
Set Over
[:]SENSe[<channel>]:TEMPerature:PROTection:LAT
Temperature
Ch <on-off-state>
Response
Query Over
[:]SENSe[<channel>]:TEMPerature:PROTection:TRI
Temperature
Pped?
Protection Tripped
Set AC Fail
[:]SENSe[<channel>]:VOLTage:AC:PROTection:LATC
Response
h <on-off-state>
Query AC Fail
[:]SENSe[<channel>]:VOLTage:AC:PROTection:TRIP
Protection Tripped
ped?

Table C-12 User Lines

Function
SCPI Command
Select polarity of
[:]OUTPut[<channel>]:AUXiliary<A|B>:POLarity
Auxiliary Lines
{HIGH|LOW}
Select Source of
[:]OUTPut[<channel>]:AUXiliary<A|B>:SOURce
Auxiliary Line State
<aux_line_mnemonic>
Query state of
[:]OUTPut[<channel>]:AUXiliary<A|B>:STATe?
Auxiliary Line
Description
Select if output is latched off or
auto recovers in the case of an
over temperature condition
Query temperature protection
tripped
Select if output is latched off or
auto recovers in the case of an AC
Fail
Query AC protection circuit
tripped
Description
Configure the polarity of the
auxiliary line
Configure the auxiliary line
Query the state of the auxiliary
line