Shipped Configuration (Local Operation)
The power supply is configured for local operation at the factory. See
Table 3-3 for a summary of this configuration. For more information on
default settings, see Table 3-9 on page 3–39.
Table 3-3 Shipped Configuration
Local Control Configuration
Use the front panel controls to
adjust the output voltage and
current set point settings.
The OVP set point is adjusted at
the front panel to 105% above the
maximum rated output voltage.
Enabling the Output
Enabling the output on will also turn off the ALARM LED if the ALARM
LED has been latched on due to an alarm triggering and automatically
clearing. See "Alarms and Errors" on page 3–18.
To enable the output power:
◆ Press the OUTPUT ENABLE Main button on the front panel or enter
To disable the output power:
◆ Press the OUTPUT ENABLE Main button when the OUTPUT
Important:
activated. See "Using the External Shutdown Function" on page 3–30.
The SCPI command (s) for these instructions are:
Quick Tip Remote
Operation uses
[:]OUTPut[<channel>][:POWer][:STATe]
these commands.
See page 5–1.
M370078-01
the SCPI command.
The OUTPUT ENABLE Main button will illuminate.
ENABLE Main button is illuminated.
The output will be disabled and the LEDs will not be illuminated.
The main output will not turn on if the shutdown function is
Enabling the Output
Additional References
See Chapter 3, "Local Operation" for front
panel operation. See Chapter 4, "Analog
Programming (APG) and Isolated Analog
Programming (ISOL)" for analog
programming procedures.
See "Using Over Voltage Protection
(OVP)" on page 3–25 for the adjustment
procedure.