Remote CONtrol Sub-Register
This identifies which remote interface is controlling the unit. Only one bit is
active at a time with the exception of analog control, where voltage or current
alone, or both may be under remote control. Current share mode is considered to
be under local control, even though the user cannot adjust the voltage setting from
the front panel.
Table 4-13 Remote CONtrol Sub-Register
Bit
Bit Weight
Bit Name
0
1
Analog Control Voltage
1
2
Analog Control Current
2
4
GPIB CONtrol
3
8
GPIB CONtrol with LLO The power supply is under Remote Control via the GPIB
4
16
RS-232 CONtrol
5
32
RS-232 Control with
LLO
6
64
Multi-channel CONtrol
7
128
Multi-channel Control
with LLO
TM-XDOP-01XN
Description
The Voltage Setpoint is under control of the Analog
Programming Interface.
The Current Setpoint is under control of the Analog
Programming interface.
The power supply is under Remote CONtrol via the GPIB
interface.
interface, with local controls locked out.
The power supply is under Remote CONtrol via the RS-232
interface.
The power supply is under Remote CONtTrol via the RS-232
interface, with local controls locked out.
The power supply is under Remote CONtrol via the Multi-
channel Programming interface.
The power supply is under Remote CONtrol via the Multi-
channel Programming interface, with local controls locked
out.
SCPI Commands for Digital Interfaces
4–49