Table C-4 Commands For Current Share - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

Table C-3 Commands for Output Control
Function
SCPI Command
Set High Current
[[:]SOURce][<channel>]:CURRent:LIMit:HIGH
Limit
{<current>|MAXimum|MINimum}
Set Low Current
[[:]SOURce][<channel>]:CURRent:LIMit:LOW
Limit
{<current>|MAXimum|MINimum}
Set High Power
[[:]SOURce][<channel>]:POWer:LIMit:HIGH
Limit
{<power>|MAXimum|MINimum}
Set Low Power
[[:]SOURce][<channel>]:POWer:LIMit:LOW
Limit
{<power>|MAXimum|MINimum}
Set High Voltage
[[:]SOURce][<channel>]:VOLTage:LIMit:HIGH
Limit
{<voltage>|MAXimum|MINimum}
Set Low Voltage
[[:]SOURce][<channel>]:VOLTage:LIMit:LOW
Limit
{<voltage>|MAXimum|MINimum}

Table C-4 Commands for Current Share

Function
SCPI Command
Set Current Sharing
[[:]SOURce][<channel>]:COMBine:CSHare:MODE
Mode
{NONE|MASTer|SLAVe}
Read Summed
[:]MEASure[:SCALar]:CURRent[:DC]? SUM
Current
Description
Set upper limit of current setpoint
range (soft limits)
Set lower limit of current setpoint
range (soft limits)
Set upper limit of power setpoint
range (soft limits)
Set lower limit of power setpoint
range (soft limits)
Set upper limit of voltage setpoint
range (soft limits)
Set lower limit of voltage setpoint
range (soft limits)
Description
Select current share mode
Read total current output of all
current sharing supplies
Query
Yes
Yes
Yes
Yes
Yes
Yes
Query
Yes
N/A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents