Table 4-9 Operation Status Register - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

Remote Operation

Table 4-9 OPERation Status Register

Bit
Bit Weight
0
1
1
2
2
4
3
8
4
16
5
32
6
64
7
128
8
256
9
512
10
1024
11
2048
12
4096
13
8192
14
16384
15
32768
4–46
Bit Name
CALibrating
SETTling
RANGing
SWEeping
MEASuring
Waiting for TRIGger
Summary
Waiting for ARM Summary
CORRecting
REGulating Summary
SHUTdown Summary
Remote CONtrol Summary
Current SHareSummary
Not Used
INSTrument Summary
PROGram Running
Not Used
Description
Indicates that the supply is in CALibration Mode.
Not implemented
Not implemented
Not implemented
Not implemented
Indicates if the supply is waiting for a TRIGger.
Not implemented
Not implemented
Reflects the summary of the REGulating Sub-Register.
Reflects the summary of the SHUTdown Sub-Register.
Reflects the summary of the Remote CONtrol Sub-
Register.
Reflects the summary of the Current Share Sub-
Register.
Not used
Not implemented
Indicates that an Automated Sequence is running.
Not used
TM-XDOP-01XN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents