Table C-7 Commands For Fold Protection; Table C-8 Commands For Triggering - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

Table C-7 Commands for Fold Protection

Function
SCPI Command
Set Output Fold
[:]OUTPut[<channel>]:PROTection:FOLD:DELay
Delay
<delay>
Set Output Fold
[:]OUTPut[<channel>]:PROTection:FOLD[:MODE]
Mode
{NONE|CC|CP|CV}
Query Fold
[:]OUTPut[<channel>]:PROTection:FOLD:TRIPped?
Protection Tripped

Table C-8 Commands for Triggering

Function
SCPI Command
Set Immediate
[:]INITiate[<channel>][:IMMediate]
Initiation of Trigger
System
Set Trigger Source
[:]TRIGger[<channel>][:SEQuence]:SOURce
{BUS|EXTernal|IMMediate|NONE}
Description
Set the delay time (seconds)
before fold protection is triggered.
Select which regulation mode to
fold back (None, CV, CC, CP)
Query if fold protection has
tripped
Description
Initiate a triggered event or
sequence
Sets the trigger source for
triggered setpoints
Query
Yes
Yes
N/A
Query
N/A
Yes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents