Remote Interlock Using A Contact Closure; Table 4-2 Analog Programming Pins; Table 4-3 Analog Pin Connections For Power Loop Back; Table 4-4 Analog Pin Connections With A Contact Closure - Xantrex XDC 10-1200 Operating Manual

Xdc 6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-1200:
Table of Contents

Advertisement

Table 4-2 Analog Programming Pins

The analog setpoint and readback pins may be configured to work in either a 0–
5V range or 0–10V range.
The programming lines have their own isolated power source (10mA max), and
this power can be looped back to power the user lines, if required. Connect the
pins as shown in Table 4-3.

Table 4-3 Analog Pin Connections for Power Loop Back

Remote Interlock Using a Contact Closure

The interlock input may be configured for use with an external voltage free
contact. Connect pins as shown:

Table 4-4 Analog Pin Connections with a Contact Closure

Closing an external contact across the interlock pins B2/A4 will then disable the
unit. Opening the contact will enable the supply output.
TM-XDOP-01XN
Pin #
Function
B1
Analog Programming (GND)
B2
12V (unregulated) 10mA max
B3
Voltage Setpoint (0–5/10V)
B4
Current Setpoint (0–5/10V)
B5
Voltage Readback (0–5/10V)
B6
Current Readback (0–5/10V)
Programming Line Pin #
B1
B2
Programming Line Pin #
B1
Input/Output
Output
Output
Input
Input
Output
Output
User Line Pin #
to
A7
to
A6
User Line Pin #
to
A5
Remote Analog Operation