The factory ships units already configured for local control (front panel) operation.
Shipped
Configuration
See Table 3.1 for a summary of this configuration. See Figure 1.1 and Figure for
front and rear panel diagrams.
(Local Control
Mode)
Table 3.1 Shipped Configuration (Local Control Mode)
Local Control Configuration
Use the front panel controls to adjust the
output voltage and current limit settings.
(Note: Use the LOCAL button only when you
have a digital programming interface
installed.)
The supply's sense point is at the rear panel
J10 sense connector terminals.
The OVP set point is adjusted at the front
panel to approximately 110% of rated output
voltage.
The over temperature shutdown function
automatically resets when activated as
determined by the position of rear panel
switch SW1-8. A latch off setting is also
available.
Release 2.1
Additional References
See Section 3 for front panel operation.
See Section 4 for remote analog
programming procedure(s).
"Local and Remote Sensing" on
See
page 53
for how to change from local to
remote sensing.
"Using Over Voltage Protection
See
(OVP)" on page 61
for the adjustment
procedure.
"Over Temperature Protection
See
(OTP)" on page 70
for more
information about switch SW1-8
settings.
Local Operation
Standard Operation
59