Set Shutdown Recovery for AC Off and OTP

The Shutdown Recovery menu offers 2 options for AC Off (ACO) and Over-
Temperature protection (OTP):
You can set either or both the OTP and AC Off to Auto-Recovery or Latched.
To set both OTP and AC Off to Auto-Recovery:
a. You can also press MENU 4 times to bring up the Shutdown Recovery option.
b. The default is Latched. You can leave it at Latched or change it to Auto-Recovery. Press
c. The default is AutoRecov. You can leave it at Auto-Recovery or change it to Latched.
TM-XDOP-01XN
Auto-Recovery: With this method, the power supply returns to its normal
operating state once the alarm condition no longer exists. For example, if
there was an over-temperature alarm and the protection was set to auto-
recovery, the power supply would return to its normal operating state once the
temperature was reduced below the alarm level.
Latched: With this method, the power supply remains in Shutdown state until
the operator manually clears the protection level and manually turns the
output back on.
Step # Do This
1
MENU
2
3 times
3
ENTER
4
5
ENTER
6
ENTER
either arrow key repeatedly until the desired option appears.
Press either arrow key repeatedly until the desired option appears.
You Will See
ERROR MSGS
S/D RECOVERY
a
b
OTP Latched
OTP AutoRecov
c
ACO AutoRecov
OTP is set to Auto Recovery.
ACO remains set to Auto Recovery and the
display returns to its default operating mode.
Power Supply Operation
3–15