14.2.14 Ethernet Ip Group; 14.2.15 Process Image Group; Table 223: Wago Mib - Ethernet Ip Group; Table 224: Wago Mib - Process Image Group - WAGO 750-363/0040-0000 Manual

Fc ethernet/ip g4 eco xtr fieldbus coupler ethernet/ip; generation 4; eco; extreme for wago-i/o-system 750
Table of Contents

Advertisement

244 Appendix

14.2.14 Ethernet IP Group

The EtherNet/IP group contains information and settings for the EtherNet/IP.
Table 223: WAGO MIB – Ethernet IP Group
Identifier
1.3.6.1.4.1.13576.10.1.40.7.1 wioEthernetIpEnable
1.3.6.1.4.1.13576.10.1.40.7.2 wioEthernetIpVariables-
1.3.6.1.4.1.13576.10.1.40.7.3 wioEthernetIpVariables-
1.3.6.1.4.1.13576.10.1.40.7.4 wioEthernetIpVariables-
1.3.6.1.4.1.13576.10.1.40.7.5 wioEthernetIpVariables-
1.3.6.1.4.1.13576.10.1.40.7.6 wioEthernetIpVariables-
1.3.6.1.4.1.13576.10.1.40.7.7 wioEthernetIpVariables-
1.3.6.1.4.1.13576.10.1.40.7.8 wioEthernetIpRunIdle-
1.3.6.1.4.1.13576.10.1.40.7.9 wioEthernetIpRunIdle-

14.2.15 Process Image Group

The process image group contains a list of information about the terminals
connected to the fielbus coupler.
Table 224: WAGO MIB – Process Image Group
Identifier
1.3.6.1.4.1.13576.10.1.50.1
1.3.6.1.4.1.13576.10.1.50.2
1.3.6.1.4.1.13576.10.1.50.3
1.3.6.1.4.1.13576.10.1.50.4
1.3.6.1.4.1.13576.10.1.50.5
1.3.6.1.4.1.13576.10.1.50.6
1.3.6.1.4.1.13576.10.1.50.7
1.3.6.1.4.1.13576.10.1.50.8
1.3.6.1.4.1.13576.10.1.50.8.1
1.3.6.1.4.1.13576.10.1.50.8.1.1 wioModuleNumber
1.3.6.1.4.1.13576.10.1.50.8.1.2 wioModuleName
Manual
Version 1.0.0
750-363/0040-0000 FC EtherNet/IP G4 ECO XTR
Entry
InputCount
OutputCount
PlcInputCount
PlcInputOffset
PlcOutputCount
PlcOutputOffset
HeaderOrginatorToTarget
HeaderTargetToOrginator
Entry
Access Description
wioModulCount
wioAnalogOutLength
wioAnalogInLength
wioDigitalOutLength
wioDigitalInLength
wioDigitalOutOffset
wioDigitalInOffset
wioModuleTable
wioModuleEntry
WAGO-I/O-SYSTEM 750
Access Description
R/W
Enable/disable the port of the
Ethernet IP server
0 = port of EtherNet/IP server
disable
1 = port of EtherNet/IP server
enable
Default value: { 0 }
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
Count of modules
R
Length of analog output process datas
R
Length of analog input process datas
R
Length of digital output process datas
R
Length of digital input process datas
R
Offset of digital output process datas
R
Offset of digital input process datas
-
-
R
Number of module slot
R
Name of module

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents