750-363/0040-0000 FC EtherNet/IP G4 ECO XTR
8.8

Restoring Factory Settings

To restore the factory settings, proceed as follows:
1.
Switch off the supply voltage of the fieldbus node.
2.
Connect the communication cable 750-920 or 750-923 respectively the
Bluetooth
the fieldbus node and to your computer.
3.
Switch on the supply voltage of the fieldbus node.
4
Start the WAGO-ETHERNET-Settings program.
5.
In the top menu bar, select [Factory Settings] and click [Yes] to confirm.
A restart of the fieldbus node is implemented automatically. The start takes place
with the default settings.
®
Adapter 750-921 to the service interface of the head station of
Commissioning 111
Manual
Version 1.0.0