Safety Advice (Precautions)

For installing and operating purposes of the relevant device to your system the
following safety precautions shall be observed:
Do not work on devices while energized!
All power sources to the device shall be switched off prior to performing any
installation, repair or maintenance work.
Install device in only one suitable enclosure!
The device is an open system. Install the device in a suitable enclosure. This
enclosure must:
Guarantee that the max. permissible degree of pollution is not exceeded.
Offer adequate protection against contact.
Prevent fire from spreading outside of the enclosure.
Offer adequate protection against UV irradiation.
Guarantee mechanical stability
Restrict access to authorized personnel and may only be opened with tools
Ensure disconnect and overcurrent protection!
The device is intended for installation in automation technology systems.
Disconnect protection is not integrated. Connected systems must be protected by
a fuse.
Provide suitable disconnect and overcurrent protection on the system side!
Ensure a standard connection!
To minimize any hazardous situations resulting in personal injury or to avoid
failures in your system, the data and power supply lines shall be installed
according to standards, with careful attention given to ensuring the correct
terminal assignment. Always adhere to the EMC directives applicable to your
application.