6. Remove and replace the AC relay module.
7. To re-install, follow these steps in reverse order.

Removing the lamp door interlock switch

Complete the following procedure to remove the lamp door interlock switch.
Estimated time to replace: 3 minutes.
1. Loosen the two quick-release screws on the lamp door.
2. Open the lamp door.
3. Disconnect the two lamp interlock switch connectors.
4. Remove the two screws securing the switch and bracket holder.
5. Remove the lamp interlock switch.
6. To re-install, follow these steps in reverse order.

Remove the AC voltmeter

Complete the following procedure to remove the AC voltmeter.
Warning! If not avoided, the following could result in death or serious injury.
SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning,
removing components, or opening any enclosure.