3. Disconnect the P80/J80 rear harness connection.
4. Remove the rear IR sensor.
5. To re-install, complete these steps in reverse order.

Remove the dual temperature sensor module #1

Complete the following procedure to remove the dual temperature sensor module (DTSM) #1.
Estimated time to replace: 2 minutes.
1. Remove the front cover (on page 36).
2. On the DTSM, disconnect the J82 connector.
3. Remove the screw securing the DTSM.
4. Remove the DTSM.
5. To re-install, complete these steps in reverse order.

Remove the dual temperature sensor module #2

Complete the following procedure to remove the dual temperature sensor module (DTSM) #2.
Estimated time to replace: 2 minutes.
1. Remove the rear cover (on page 37).
2. On the DTSM, disconnect the J82 connector.
3. Remove the screw securing the DTSM.
J Series Service Guide–2.0, 2.4, and 3.0 kW