11. Attach the two slide rollers to the large slider.
12. Thread the connector harness through the cutouts on the large slider.
13. Mount the large slider to the front plate.
14. Align the small slider over the large slider and secure with the two screws removed in step 7.
15. Torque the screws to 8 in-lb.
If the slider does not move freely, loosen the screws just enough to allow movement.
16. Secure the spring to the small slider plate with the screw removed in step 6.
17. Tighten the screw until the screw head is at the same height as the spring.
18. Mount the front plate back onto the middle plate of the lens mount.
19. Position the connector with the mounting points on the large slider.
Ensure that the chamfer (F) is oriented as shown.
20. Replace all the screws removed in step 3.
21. Replace the two screws removed in step 2.
22. Attach the lens mount.

Removing the lens on a CT lens mount

Complete the following procedure to remove the lens.
Estimated time to replace: 1 minute.
1. If installed, remove and retain the red security screws from the lens mount.
J Series Service Guide–2.0, 2.4, and 3.0 kW
020-100739-05 Rev. 1 (02-2018)