Flexible Mailbox Numbering Plan; Flexible Numbering Plan Example - NEC IntraMail UX5000 Manual

Hide thumbs Also See for IntraMail UX5000:
Table of Contents

Advertisement

Flexible Mailbox Numbering Plan

Flexible Mailbox Numbering Plan
Description
If extension numbers are customized, set up IntraMail mailbox numbers to match.
Flexible Mailbox Numbering Plan lets you customize a site's extension numbers and be assured that Intra-
Mail will adapt to the new configuration. When you change a port's extension number, you can change the
number of the mailbox assigned to that port to match. There is no need to reprogram — all of the options
remain intact.
Conditions
None
Default Setting
Available
Programming

Flexible Numbering Plan Example

1.
Optionally change the number of digits in extension numbers.
11-01-01: S
2.
Change the extension number associated with a port.
11-02-01 : E
3.
Change the mailbox number to match the new extension number.
47-02-02: M
4.
Modify the Dial Action Tables to accommodate the new numbering.
47-13: I
108 ◆ IntraMail Features
N
YSTEM
UMBERING
Optionally change the number of digits required to reach each range of extensions.
✔ By default, 3-digit extension numbers are 200-299, 300-399, 400-499, 600-699, and 700-799.
✔ By default, 4-digit extension numbers are 5000-5999.
N
XTENSION
UMBERING
Assign extension numbers to extension ports.
- The extension's programming identity follows the port number - not the extension number.
✔ ?By default, extension-to-port assignments are consecutive starting with 301 (e.g., port
001=extension 301, port 002=extension 302, etc.).
N
(
252)
AILBOX
UMBER
PAGE
Change the mailbox number to match the number of the new extension.
✔ By default, mailbox numbers are consecutively assigned for the first 64 mailboxes (e.g.,
mailbox 1=mailbox number 301, mailbox 2=mailbox number 302, etc.).
M
D
A
T
NTRA
AIL
IAL
CTION
ABLES
Optionally modify the active Dial Action Table actions for the new extension numbers.
- For example, to allow Automated Attendant callers to dial extension 5000, for digit 5:
- Change the Action to UTRF (2) or TRF (1).
- Change the Data to XXXX.
✔ By default (in the above example), the digit 5 is undefined.
(
295)
PAGE
UX IntraMail Manual

Advertisement

Table of Contents
loading

Table of Contents