Type 3 (Date) Answer Schedule Options; Type 3 (Date) Example - NEC IntraMail UX5000 Manual

Hide thumbs Also See for IntraMail UX5000:
Table of Contents

Advertisement

Program 47: IntraMail

Type 3 (Date) Answer Schedule Options

Type 3 (Date) Example

In this example, Answer Table 1 routes calls as follows:
Schedule 1 uses Routing Mailbox 1 and runs every day from 8:30AM to 5:00PM.
Schedule 2 uses Routing Mailbox 9 and runs only on Christmas day from 8:30AM to 5:00PM.
At all other times, routing is handled by the Default Mailbox specified in
C
ATEGORY
When setting up Answer Tables with multiple types, build the Answer Schedules in the following order:
Range of Days
Day of Week
Date
Answer Table 1
Answer Schedule 1
Answer Schedule 1 is a Range of Days schedule that starts schedule that runs every day from 8:30AM to 5:00PM.
Answer Schedule 2
Answer Schedule 2 is a Date schedule that runs only on Christmas day from 8:30AM to 5:00PM.
294 ◆ IntraMail Programming
and
47-11-03: D
EFAULT
Type 3 (Date) Example
47-12-01: Entry01 Schedule Type = 2
47-12-02: Entry01 MB Ctg = 3
47-12-02: Entry01 MB Num = 1
47-12-03: Entry01 Day = 1 (Entry doesn't matter)
47-12-04: Entry01 Start Day = 1 (Sunday)
47-12-05: Entry01 End Day = 1 (Sunday)
47-12-06: Entry01 Date (MMDD) = 0000 (Entry doesn't matter)
47-12-07: Entry01 Start Time = 0830 (8:30AM)
47-12-08: Entry01 End Time = 1700 (5:00PM)
47-12-01: Entry01 Schedule Type = 3
47-12-02: Entry01 MB Ctg = 3
47-12-02: Entry01 MB Num = 9
47-12-03: Entry01 Day = 1 (Entry doesn't matter)
47-12-04: Entry01 Start Day = 1 (Entry doesn't matter)
47-12-05: Entry01 End Day = 1 (Entry doesn't matter)
47-12-06: Entry01 Date (MMDD) = 1225 (December 25, Christmas day)
47-12-07: Entry01 Start Time = 0830 (8:30AM)
47-12-08: Entry01 End Time = 1700 (5:00PM)
.
M